1 open-circuit fault
English-German dictionary of Electrical Engineering and Electronics > open-circuit fault
-
2 open circuit fault
n ELECTRON Unterbrechungsfehler m -
3 нарушение непрерывности цепи
нарушение непрерывности цепи
Состояние, характеризующееся случайным возникновением относительно высокого значения сопротивления между двумя точками данного проводника.
[ ГОСТ Р МЭК 60050-195-2005]EN
(conductor) continuity fault
state of an item characterized by the accidental presence of a relatively high impedance between two points of the same conductor
Source: 448-13-06 MOD
[IEV number 195-04-15]FR
défaut série
état d'une entité caractérisé par la présence accidentelle d'une impédance relativement élevée entre deux points d'un même conducteur
Source: 448-13-06 MOD
[IEV number 195-04-15]Тематики
- электротехника, основные понятия
Синонимы
EN
DE
FR
Русско-немецкий словарь нормативно-технической терминологии > нарушение непрерывности цепи
-
4 распределительное устройство
распределительное устройство
Распределительным устройством (РУ) называется электроустановка, служащая для приема и распределения электроэнергии и содержащая сборные и соединительные шины, коммутационные аппараты, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
[РД 34.20.185-94]
распределительное устройство
Электроустановка, предназначенная для приема и распределения электрической энергии на одном напряжении и содержащая коммутационные аппараты и соединяющие их сборные шины [секции шин], устройства управления и защиты.
Примечание. К устройствам управления относятся аппараты и связывающие их элементы обеспечивающие контроль, измерение, сигнализацию и выполнение команд.
[ ГОСТ 24291-90]
[ ГОСТ Р 53685-2009]
электрическое распределительное устройство
распределительное устройство
Устройство, предназначенное для приема и распределения электроэнергии на одном напряжении и содержащее коммутационные аппараты и соединяющие их сборные соединительные устройства.
Примечание. В состав распределительного устройства дополнительно могут входить устройства защиты и управления
[ОСТ 45.55-99]
распределительное устройство
Электроустановка, служащая для приема и распределения электроэнергии и содержащая коммутационные аппараты, сборные и соединительные шины, вспомогательные устройства (компрессорные, аккумуляторные и др.), а также устройства защиты, автоматики и измерительные приборы.
[ПОТ Р М-016-2001]
[РД 153-34.0-03.150-00]
устройство распределительное
Совокупность аппаратов и приборов для приёма и распределения электроэнергии одного напряжения, вырабатываемой электростанцией или преобразуемой подстанцией
[Терминологический словарь по строительству на 12 языках (ВНИИИС Госстроя СССР)]EN
switching substation
a substation which includes switchgear and usually busbars, but no power transformers
[IEV number 605-01-02]FR
poste de sectionnement
poste de coupure
poste comprenant des organes de manoeuvre et généralement des jeux de barres, à l'exclusion de transformateurs de puissance
[IEV number 605-01-02]В качестве РУ 6—10 кВ используется сборка высокого напряжения с однополюсными разъединителями и вертикальным расположением фаз одного присоединения и одна камера КСО с выключателем нагрузки и предохранителями для подключения трансформатора. Для РУ 0,4 кВ применяются сборки низкого напряжения с предохранителями и вертикальным расположением фаз одного присоединения.
На ПС применяются открытые (ОРУ), закрытые (ЗРУ) или комплектные (КРУ) распределительные устройства.
[ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]
В общем случае ПС и РУ являются составной частью электроустановок, которые различаются:
-
по назначению:
- генерирующие,
- преобразовательно-распределительные,
-
потребительские.
Генерирующие электроустановки служат для выработки электроэнергии, преобразовательно-распределительные электроустановки преобразуют электроэнергию в удобный для передачи и потребления вид, передают ее и распределяют между потребителями;
-
по роду тока:
- постоянного тока,
- переменного тока.
-
по напряжению:
- до 1000 В,
- выше 1000 В.
ГОСТ 29322—92 установлена следующая шкала номинальных напряжений:
Шкала номинальных напряжений ограничена сравнительно небольшим числом стандартных значений, благодаря чему изготавливается небольшое число типоразмеров машин и оборудования, а электросети выполняются более экономичными. В установках трехфазного тока номинальным напряжением принято считать напряжение между фазами (междуфазовое напряжение). Согласнодля электросетей переменного тока частотой 50 Гц междуфазовое напряжение должно быть: 12, 24, 36, 42, 127, 220, 380 В; 3, 6, 10, 20, 35, 110, 150, 220, 330, 500, 750 и 1150 кВ;
для электросетей постоянного тока: 12, 24, 36, 48, 60, 110, 220, 440, 660, 825, 3000 В и выше.-
по способу присоединения к электросети ПС разделяются на:
- тупиковые (блочные),
- ответвительные (блочные),
- проходные (транзитные)
- узловые.
Тупиковые ПС получают питание по одной или двум тупиковым ВЛ.
Ответвительные ПС присоединяются ответвлением к одной или двум проходящим ВЛ с односторонним или двухсторонним питанием.
Проходные ПС включаются в рассечку одной или двух проходящих ВЛ с односторонним или двухсторонним питанием.
Узловые ПС кроме питающих имеют отходящие радиальные или транзитные ВЛ.-
по способу управления ПС могут быть:
- только с телесигнализацией,
- телеуправляемыми с телесигнализацией,
- с телесигнализацией и управлением с общеподстанционного пункта управления (ОПУ).
Подстанции оперативно обслуживаются постоянным дежурным персоналом на щите управления, дежурными на дому или оперативно-выездными бригадами (ОВБ). Ремонт ПС осуществляется специализированными выездными бригадами централизованного ремонта или местным персоналом подстанции.
В РУ напряжением до 1000 В провода, шины, аппараты, приборы и конструкции выбирают как по нормальным условиям работы (напряжению и току), так и по термическим и динамическим воздействиям токов коротких замыканий (КЗ) или предельно допустимой отключаемой мощности.
В РУ и ПС напряжением выше 1000 В расстояния между электрооборудованием, аппаратами, токоведущими частями, изоляторами, ограждениями и конструкциями устанавливаются так, чтобы при нормальном режиме работы электроустановки возникающие физические явления (температура нагрева, электрическая дуга, выброс газов, искрение и др.) не могли привести к повреждению оборудования и КЗ.[ http://energy-ua.com/elektricheskie-p/klassifikatsiya.html]
Several different classifications of switchgear can be made:- By the current rating.
-
By interrupting rating (maximum short circuit current that the device can safely interrupt)
- Circuit breakers can open and close on fault currents
- Load-break/Load-make switches can switch normal system load currents
- Isolators may only be operated while the circuit is dead, or the load current is very small.
-
By voltage class:
- Low voltage (less than 1,000 volts AC)
- Medium voltage (1,000–35,000 volts AC)
- High voltage (more than 35,000 volts AC)
-
By insulating medium:
-
By construction type:
- Indoor (further classified by IP (Ingress Protection) class or NEMA enclosure type)
- Outdoor
- Industrial
- Utility
- Marine
- Draw-out elements (removable without many tools)
- Fixed elements (bolted fasteners)
- Live-front
- Dead-front
- Open
- Metal-enclosed
- Metal-clad
- Metal enclosed & Metal clad
- Arc-resistant
-
By IEC degree of internal separation
- No Separation (Form 1)
- Busbars separated from functional units (Form 2a, 2b, 3a, 3b, 4a, 4b)
- Terminals for external conductors separated from busbars (Form 2b, 3b, 4a, 4b)
- Terminals for external conductors separated from functional units but not from each other (Form 3a, 3b)
- Functional units separated from each other (Form 3a, 3b, 4a, 4b)
- Terminals for external conductors separated from each other (Form 4a, 4b)
- Terminals for external conductors separate from their associated functional unit (Form 4b)
-
By interrupting device:
-
By operating method:
- Manually operated
- Motor/stored energy operated
- Solenoid operated
-
By type of current:
-
By application:
-
By purpose
- Isolating switches (disconnectors)
- Load-break switches.
- Grounding (earthing) switches
A single line-up may incorporate several different types of devices, for example, air-insulated bus, vacuum circuit breakers, and manually operated switches may all exist in the same row of cubicles.
Ratings, design, specifications and details of switchgear are set by a multitude of standards. In North America mostly IEEE and ANSI standards are used, much of the rest of the world uses IEC standards, sometimes with local national derivatives or variations.
[Robert W. Smeaton (ed) Switchgear and Control Handbook 3rd Ed., Mc Graw Hill, new York 1997]
[ http://en.wikipedia.org/wiki/High_voltage_switchgear]Тематики
- электрификация, электроснабж. железных дорог
- электроагрегаты генераторные
- электробезопасность
- электроснабжение в целом
Синонимы
EN
- distribution
- energy distribution board
- gear
- switch-gear
- switchboard
- switchgear
- switching substation
- switchyard
DE
FR
Русско-немецкий словарь нормативно-технической терминологии > распределительное устройство
-
по назначению:
-
5 вакуумный выключатель
выключатель вакуумный
Выключатель, контакты которого размыкаются и замыкаются в оболочке с высоким вакуумом.
[ ГОСТ Р 52565-2006]EN
vacuum circuit-breaker
a circuit-breaker in which the contacts open and close within a highly evacuated envelope
[IEV number 441-14-29]FR
disjoncteur à vide
disjoncteur dont les contacts s'ouvrent et se ferment dans une enceinte où règne un vide poussé
[IEV number 441-14-29]В последнее время интенсивно развиваются конструкции вакуумных выключателей, в которых контактная система помещена в вакуумную камеру. Такие выключатели изготавливаются на напряжение до 35 кВ включительно. Их отличительная особенность — погасание дуги при первом же переходе тока через ноль (после расхождения контактов) и в связи с этим чрезвычайно большой ресурс — до тысяч операций и более.
[А. И. Афанасьев и др. Электрические аппараты высокого напряжения. - 2-е изд., доп. СПбГТУ, 2000, 503 с.]
Вакуумный выключатель среднего напряженияТематики
- выключатель, переключатель
- высоковольтный аппарат, оборудование...
EN
- vacuum breaker
- vacuum circuit breaker
- vacuum circuit-breaker
- vacuum fault interrupter
- vacuum interrupting unit
- vacuum switch
- vacuum-operated switch
- VCB
- VIU
- VS
DE
FR
Русско-немецкий словарь нормативно-технической терминологии > вакуумный выключатель
См. также в других словарях:
Circuit breaker — For other uses, see Circuit breaker (disambiguation). An air circuit breaker for low voltage (less than 1000 volts) power distribution switchgear … Wikipedia
Fault model — A fault model is an engineering model of something that could go wrong in the construction or operation of a piece of equipment. From the model, the designer or user can then predict the consequences of this particular fault. Fault models can be… … Wikipedia
Semiconductor fault diagnostics — are predictive software algorithms which are used to refine and localize the circuitry responsible for the failure of scan based devices. [cite conference| last=Crowell| first=G| coauthors=Press, R.| title=Using Scan Based Techniques for Fault… … Wikipedia
Short circuit — A short circuit (sometimes abbreviated to short or s/c) allows a current along a different path from the one intended. The electrical opposite of a short circuit is an open circuit , which is an infinite resistance between two nodes. It is common … Wikipedia
Arc-fault circuit interrupter — An arc fault circuit interrupter (AFCI) is a circuit breaker designed to prevent fires by detecting non working electrical arcs and disconnect power before the arc starts a fire. The AFCI should distinguish between a working arc that may occur in … Wikipedia
2009 US Open (tennis) — 2009 US Open Date: August 31 – September 14 Edition: 129th Category: … Wikipedia
Track circuit — A track circuit is a simple electrical device used to detect the presence or absence of a train on rail tracks, used to inform signallers and control relevant signals. Principles and operation The basic principle behind the track circuit lies in… … Wikipedia
обрыв цепи — — [Интент] Параллельные тексты EN RU The P63x has detected an open circuit in the connection of the resistance thermometer. [Schneider Electric] Устройство P63x обнаружило обрыв цепи термометра сопротивления. [Перевод Интент] Тематики… … Справочник технического переводчика
Solenoid voltmeter — A solenoid voltmeter is a specific type of voltmeter used by electricians in the testing of electrical power circuits. Wiggy is the registered trademark for a common solenoid voltmeter used in North America and manufactured by Square D, derived… … Wikipedia
нарушение непрерывности цепи — Состояние, характеризующееся случайным возникновением относительно высокого значения сопротивления между двумя точками данного проводника. [ГОСТ Р МЭК 60050 195 2005] EN (conductor) continuity fault state of an item characterized by the… … Справочник технического переводчика
повреждение с разрывом цепи — — [Я.Н.Лугинский, М.С.Фези Жилинская, Ю.С.Кабиров. Англо русский словарь по электротехнике и электроэнергетике, Москва, 1999 г.] Тематики электротехника, основные понятия EN open circuit fault … Справочник технического переводчика